The megger ducter dlro10 and ducter dlro10x bring new standards to low resistance measurement. Equipment connected between the electrical outlets and the users equipment. A wide range of academic papers, application notes, technical guides, software updates and a range of other documentation is available in our technical library. The mft1741 is iec 61010 cat iv 300 v rated for safe connection anywhere within.
We have 1 megger mit525 manual available for free pdf download. Enclosed in a tough case it is both smaller and lighter than its predecessor making it even easier to carry and store. Megger makes electrical test equipment to help you install, improve efficiency and extend the life of electrical assets and cable networks at high, medium and low voltage. The latest ttr available from megger is the ttr1001, a handheld, robust, lightweight and battery operated instrument. Aemc instruments certifies that this instrument has been calibrated using standards and instruments traceable to international. Biddle megger user manuals click on a modelcatalog number for the data sheet.
Instruction manual avtm ttr100 for singlephase handheld. View and download megger pat32 series user manual online. Metercenter is a national distributor for megger, formally james g. Megger ltw425 manuals and user guides, test equipment.
Megger s automatic portable oil test sets perform accurate breakdown voltage tests on mineral, ester and silicon insulating liquids. The transparent, shielded lid is a key feature enabling users to see what. Thank you for purchasing the megger earth ground electrode tester. I january 2009 instruction manual megger pa9series user and megpa9iec software manual m valley forge corporate center 2621 van buren avenue norristown, pa 19403 u. View and download megger mit510 user manual online. The transparent, shielded lid and large test chamber enable easy access to the test vessel. View online or download megger mit4202 user manual. The fluke model 1507 and model 1503 are batterypowered insulation testers hereafter, the. The megger technical library provides access to a range of additional content and resources such as technical guides, application notes and more. This ttr will complement several existing megger transformer test products and will offer functions, such as winding resistance and polarity. Improved productivity operate from line powermains if battery dead. For users who desire more control over the measurement process, dlro 10x uses a menu. The megger mit400 series instruments are supplied with batteries fitted.
For complete operational instructions, refer to the users manual contained on the accompanying cd. Thank you for purchasing the megger earth ground tester. Circuit connections must not be touched during an insulation test. User manuals, guides and specifications for your megger ltw425 test equipment. If your unit is not listed please feel free to contact us at. Moulded test vessels give repeatable results with lock in precision electrode gap setting adjustment wheels. Download the zip file and directly unzip it to a clean. Megger s automatic laboratory oil test sets perform accurate breakdown voltage tests on mineral, ester and silicon insulating liquids.
When batteries become exhausted, refer to section17 for battery replacement. This energy is released in the form of a discharge current. Introduced after extensive customer research into the requirements of electrical contractors, these innovative instruments combine rugged. If your unit is not listed please feel free to contact. Database contains 1 megger mprt 8430 manuals available for free online viewing or downloading in pdf. View and download megger mft1700 series user manual online. Safety warnings mit400 series insulation testers safety warnings and precautions must be read and understood before the instrument is used. Instruction manual bite 2 and bite 2p battery impedance test equipment. Even if they are inadvertently connected to a live threephase supply, rcd testers in megger s rcdt300 range remain undamaged, and present no safety hazard to the user. User manuals, guides and specifications for your megger avo410 measuring instruments, multimeter. This user manual describes the operation and functions of the det series of earth ground testers. Offering cat iv, the mit1025 is compact, light 10 kv insulation resistance tester for the diagnostic testing and maintenance of high voltage electrical equipment.
M avtm246004 bite 22p rev 4 july 2011 4 bite 22p measurements impedance readings are calibrated to 5 percent of reading over the specified temperature range. Database contains 1 megger ltw425 manuals available for free online viewing or downloading in pdf. These are the most commonly requested operating manuals from megger programma. It provides a ripplefree variable dc voltage that can easily accommodate a high, variable load. As we are an official distributor for megger in ireland, we can source all supporting documentation from the manufacturer if you cant find the operating manual you are looking for in the list below, just contact us directly. Multifunction tester with loop confidence meter mft1741 megger. Your megger account allows you to register your equipment for warranty, and access a wide range of support material including software updates and technical documents. Users of megger products in the uk may dispose of them at the end of their useful life by contacting b2b compliance at uk or by telephone on 01691 676124. User manuals, guides and specifications for your megger mprt 8430 test equipment.
The mft1741 offers a wide range of test functions, designed for all electrical installation testing and verification of low voltage building wiring and distribution testing scenarios. The megohmmeter model 1015 is a true megohmmeter analog in strument. View and download megger pat4dv3 user manual online. Det series earth ground electrode testers user guide. Moulded test vessels give repeatable results in the field and laboratory with lock in precision electrode gap setting adjustment wheels. Examine the contents for damage received during transit. Rcdt300 series residual current device testers megger.
Each fluke product is warranted to be free from defects in material and workmanship under normal use. Do not switch the instrument on or connect test leads with the battery cover removed. Circuit terminals must not be touched during an insulation test or before suitable grounding of the unit under test is in place in line with safe working practices. Although this manual describes the operation of both. If you have a question on a product please take a look our faqs or take a look at some of our demonstration videos. Megger operating manuals official distributor for megger. Users of megger products in other parts of the eu should contact their local megger company or distributor. Megger is registered in the uk as a producer of batteries. Electrical test equipment support, faqs and guides megger. Ttr100 highvoltage equipment read the entire manual before operating. In this manual, the symbol preceding instructions indicates that if the instructions are not followed, bodily injury, installationsample and product damage may result. Mft1710, mft1720, mft1730, mft1800 series, mft1815, mft1825, mft1835.
Electrical test equipment power station to plug megger. For after sales support browse our customer support area. Mit300 series insulation and continuity testers megger. Megger mit1025 insulation resistance tester manual pdf. This version of megger mit4002 manual compatible with such list of devices, as. View and download megger det14c user manual online. Megger limited archcliffe road dover kent ct17 9en england. Database contains 2 megger avo410 manuals available for free online viewing or downloading in pdf. This instrument provides significantly enhanced compliance and is capable of delivering 10 a while measuring up to 250 m. The voltage at the parts marked with this symbol may be dangerous.
Both are fully automatic instruments, selecting the most suitable test current, up to 10 a dc to measure resistance from 0. This user manual describes the operation and functions of the det series of. The maximum test current available is dependent upon the power supply, the resistance of the test leads and the resistance of the item being tested. Det3ta det3tc det3td det4td2 det4tr2 det4tc2 det4tcr2 iclamp vclamp calibration adaptor twoclamp calibration adaptor these instruments are designed and manufactured by. M 2621 van buren ave norristown, pa 19403 2329 6106768500. The mft1700 series multifunction tester is a compact instrument designed to perform all of the functions required by the electrical contractor to fully test domestic, commercial and industrial. Congratulations on your purchase of a genuine megger multifunction tester. Make sure the circuit is not reenergised whilst the instrument is connected.
Page 1 mit510 5kv digital insulation tester user manual page 2 safety warnings the circuit under test must be switched off, deenergised, isolated and checked to be safe before insulation test connections are made. After testing an inductive load there will be an amount of energy stored in the inductance. Megger mprt 8430 manuals and user guides, test equipment. View and download megger ltw315 user manual online.
1598 325 1123 863 499 1423 898 456 260 1635 251 105 146 1103 1109 791 1176 10 1646 992 606 549 426 779 84 1380 1338 1569 135 864 951 705 974 1132 1465 1498 243 1271 1092 1310 323